PDA

View Full Version : Is my hard drive on the way out?



forrest44
18-12-2011, 04:42 PM
Just got a new 1TB Samsung HD103SI drive last week

I installed linux + windows on two separate partitions one evening, all appeared well
Came back the next day and Linux wouldn't boot due to some filesystem errors!

Reinstalled and everything has since been fine

Should I be concerned??
Is the drive "burning itself in"??


Did a full error scan with HDtune, which came back OK
Smart data etc looks OK I guess...

I've posted the output of smartctl --all /dev/sda below:


smartctl 5.40 2010-10-16 r3189 [i486-slackware-linux-gnu] (local build)
Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net

=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F2 EG series
Device Model: SAMSUNG HD103SI
Serial Number: S20XJD1B305218
Firmware Version: 1AG01118
User Capacity: 1,000,204,886,016 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 3b
Local Time is: Sun Dec 18 16:41:49 2011 NZDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (12761) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 214) minutes.
Conveyance self-test routine
recommended polling time: ( 23) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0007 045 045 011 Pre-fail Always - 16990
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 28
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 11063
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 59
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 25
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 082 070 000 Old_age Always - 18 (Min/Max 14/18)
194 Temperature_Celsius 0x0022 077 068 000 Old_age Always - 23 (Min/Max 14/23)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 414708
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 1
200 Multi_Zone_Error_Rate 0x000a 100 099 000 Old_age Always - 5
201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0

SMART Error Log Version: 1
ATA Error Count: 1
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
When the command that caused the error occurred, the device was active or idle.

After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 53 00 00 00 00 e0 Error: ICRC, ABRT at LBA = 0x00000000 = 0

Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 00 00 00 e0 0a 00:27:38.890 READ DMA
ef 03 42 00 00 00 a0 0a 00:27:38.880 SET FEATURES [Set transfer mode]
ec 00 00 00 00 00 a0 0a 00:27:38.870 IDENTIFY DEVICE
00 00 01 01 00 00 a0 00 00:27:38.720 NOP [Abort queued commands]
00 00 01 01 00 00 a0 ff 00:27:30.640 NOP [Abort queued commands]

SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3 -

SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.